NewEvery arXiv paper, its researchers & institutions — mapped.
paper

217 km long distance photon-counting optical time-domain reflectometry based on ultra-low noise up-conversion single photon detector

arXiv:1308.0512 · doi:10.1364/OE.21.024674

Abstract

We demonstrate a photon-counting optical time-domain reflectometry with 42.19 dB dynamic range using an ultra-low noise up-conversion single photon detector. By employing the long wave pump technique and a volume Bragg grating, we reduce the noise of our up-conversion single photon detector, and achieve a noise equivalent power of -139.7 dBm/sqrt(Hz). We perform the OTDR experiments using a fiber of length 216.95 km, and show that our system can identify defects along the entire fiber length with a distance resolution better than 10 cm in a measurement time of 13 minutes.

6 pages, 3 figures