Sub-femtotesla scalar atomic magnetometer using multipass cells

arXiv:1208.1099 · doi:10.1103/PhysRevLett.110.160802

Abstract

Scalar atomic magnetometers have many attractive features but their sensitivity has been relatively poor. We describe a Rb scalar gradiometer using two multi-pass optical cells. We use a pump-probe measurement scheme to suppress spin-exchange relaxation and two probe pulses to find the spin precession zero crossing times with a resolution of 1 psec. We realize magnetic field sensitivity of 0.54 fT/Hz$^{1/2}$, which improves by an order of magnitude the best scalar magnetometer sensitivity and surpasses the quantum limit set by spin-exchange collisions for a scalar magnetometer with the same measurement volume operating in a continuous regime.

5 pages, 4 figures