Monitoring the Bragg peak location of 73 MeV/u carbon ions by means of prompt $γ$-ray measurements

arXiv:0809.0185 · doi:10.1063/1.2975841

Abstract

By means of a time-of-flight technique, we measured the longitudinal profile of prompt $γ$-rays emitted by 73 MeV/u $^{13}$C ions irradiating a PMMA target. This technique allowed us to minimize the shielding against neutrons and scattered $γ$-rays, and to correlate prompt gamma emission to the ion path. This correlation, together with a high counting rate, paves the way toward real-time monitoring of the longitudinal dose profile during ion therapy treatments. Moreover, the time correlation between the prompt gamma detection and the transverse position of the incident ions measured by a beam monitor can provide real-time 3D control of the irradiation.

to be published in Applied Physics Letters