Vibration Combined High Temperature Cycle Tests for Capacitive MEMS Accelerometers

arXiv:0801.1030

Abstract

In this paper vibration combined high temperature cycle tests for packaged capacitive SOI-MEMS accelerometers are presented. The aim of these tests is to provide useful Design for Reliability information for MEMS designers. A high temperature test chamber and a chopper-stabilized read-out circuitry were designed and realized at BME - DED. Twenty thermal cycles of combined Temperature Cycle Test and Fatigue Vibration Test has been carried out on 5 samples. Statistical evaluation of the test results showed that degradation has started in 3 out of the 5 samples.

Submitted on behalf of TIMA Editions (http://irevues.inist.fr/tima-editions)