Mechanical losses in low loss materials studied by Cryogenic Resonant Acoustic spectroscopy of bulk materials (CRA spectroscopy)
arXiv:0709.2124 · doi:10.1088/1742-6596/92/1/012095
Abstract
Mechanical losses of crystalline silicon and calcium fluoride have been analyzed in the temperature range from 5 to 300 K by our novel mechanical spectroscopy method, cryogenic resonant acoustic spectroscopy of bulk materials (CRA spectrocopy). The focus lies on the interpretation of the measured data according to phonon-phonon interactions and defect induced losses in consideration of the excited mode shape.
4 pages, 4 figures, proceedings of the PHONONS 2007, submitted to Journal of Physics: Conference Series